ASD535-1
The ASD535 range is an early fire detection range using aspirating smoke detectors. is suitable for the surveillance of large areas and a wide range of applications: high-bay warehouses, deep-freezing areas, historic buildings, large warehouses, etc.
Highly tolerant to dust, dirt, humidity or steam disturbed environments.
It works with a highly sensitive 533 SSD sensor, its sensitivity of 0,002% Obs/m corresponds to an extremely low amount of smoke in the air, offering early detection
SECURITON
Aspirating smoke detector for 1 SSD smoke sensor 535
No smoke level indicator
Pipeline up to 400 meters in length
EN 54-20
Area under surveillance 5760 m2
IP 54
Not Available For Sale 0.0 EUR
ASD535-4
The ASD 535-4 is an aspirating smoke detector that supports up to two aspirating tubes and features a smoke level indicator built into the control unit, enabling accurate visual monitoring. Thanks to its airflow monitoring system, it ensures early detection of blockages or breaks in the piping, guaranteeing continuous and reliable operation. Compatible with ASD PipeFlow for precise calculation and design.
SECURITON
Aspiration smoke detector
Option to use 1 or 2 SSD smoke detectors 535
High-precision smoke detection
Highly Reliable Continuous Suction
Advanced Management of Two Suction Tubes
Panel-mounted smoke level indicator
Certified in accordance with EN standard 54-2
Rugged design for harsh environments
SSD sensors 535 not included
Not Available For Sale 0.0 EUR
ASD535-3
The ASD535-3 is a highly sensitive laser aspirating smoke detector, designed for early detection, with a single pipe line and front smoke level display. Pipeline airflow monitoring, self-learning function and automatic fouling compensation, ensuring early detection and stability with very low false alarm rate. Complies with EN 54‑20
SECURITON
Aspirating smoke detector for 1 SSD smoke sensors 535
1 Suction channel
With smoke level indicator
Coverage of 2400 m2
1 pipe of 300 meters length
EN 54-20
IP 54
Not Available For Sale 0.0 EUR
ASD2001
The ASD2001 is a smoke detection unit designed for early fire detection. The system works by continuously sampling air through a network of pipes and sending the samples to an optimized detection chamber.
This model stands out for its ease of installation and setup, allowing users to directly configure the alarm and pre-alarm levels. It features intelligent airflow monitoring that instantly detects any breaks in the tubing or potential blockages.
Its advanced signal processing filters out dust particles to prevent false alarms
Compatibility with ASD PipeFlow software ensures an accurate and certified pipeline network design.
Single-channel aspirating smoke detector (ASD)
IN 54-20 (Classes A, B, and C)
Up to 400 m (depending on settings and class)
Fully modular system for easy replacement
Alarm, Pre-alarm, and Fault Output Relays
Noise level from 25 dB(A) to 39 dB(A) (depending on speed)
Setup via the app using Bluetooth and design with ASD PipeFlow
Sensor SSD1030 not included
Not Available For Sale 0.0 EUR
ASD2002
The ASD2002 is a dual-channel aspirating detection system. This unit allows you to connect two separate pipe networks, each with its own smoke sensor. This allows you to monitor two separate zones with a single unit, accurately identifying which of the two channels has detected a fire.
It is an extremely efficient solution for environments where the goal is to optimize hardware without compromising early detection. It features a powerful ventilation unit and high-tech smoke sensors SSD1030 that filter out dust particles, ensuring exceptional operational stability even under demanding environmental conditions.
Compatibility with ASD PipeFlow software ensures an accurate and certified pipeline network design.
Securiton
Two-channel independent aspirating smoke detector (ASD)
Up to 400 m (depending on settings and class)
Fully modular system for easy replacement
Alarm, Pre-alarm, and Fault Output Relays
Noise level from 25 dB(A) to 39 dB(A) (depending on speed)
Setup via the app using Bluetooth and design with ASD PipeFlow
Sensor SSD1030 not included
Not Available For Sale 0.0 EUR
ASD2004
The ASD2004 is an intake unit featuring four separate pipe inlets, each equipped with its own airflow sensor. This makes it possible to detect whether there is a break or a blockage in any of the four lines.
For smoke detection, the device features two SSD smoke sensors. The air from channels 1 and 2 is combined and analyzed by the first sensor, while the air from channels 3 and 4 is analyzed by the second. This configuration offers excellent cost-effectiveness by dividing the system into two separate smoke detection zones while maintaining integrity monitoring across four pipe networks.
Compatibility with ASD PipeFlow software ensures an accurate and certified pipeline network design.
Securiton
Aspirating smoke detector (ASD) with 4 independent channels
2 SSD sensors (1 for channels 1+2 / 1 for channels 3+4)
Fully modular system for easy replacement
Up to 700 m (depending on settings and class)
Alarm, pre-alarm, and individual fault output relays per channel
Noise level from 25 dB(A) to 39 dB(A) (depending on speed)
Setup via the app using Bluetooth and design with ASD PipeFlow
Sensor SSD1030 not included
Not Available For Sale 0.0 EUR
ASD533-1
The ASD 533-1 model is specifically configured for managing a suction tube and connecting a smoke sensor. The equipment includes a calorimetric air flow monitoring system, which detects obstructions or breaks in the duct, ensuring constant monitoring.
Allows for adjustments using the "ASD Config" software or the "EasyConfig" commissioning procedures
Duct-mounted smoke detector
SSD533 Sensor
Up to 200m of pipeline
High-precision continuous smoke detection
Compact design for facility surveillance
Rapid response to early-stage fires
Ideal for areas that are technically difficult to access
Maximum reliability in extreme environments
Advanced air intake technology
Approved in accordance with EN 54-20
Not Available For Sale 0.0 EUR
ASD532-3
The ASD 532 is an aspirating smoke detector designed to detect fires in their early stages. It works by continuously sampling air from the area to be monitored, which is then channeled through a system of pipes to a highly sensitive smoke sensor, SSD532-3
SECURITON
Aspirating smoke detector, 1 sampling tube (without smoke sensor)
Pipe length up to 120 m
Maximum area 1280 m2
Complies with EN 54-20, Class A, B and C
Not Available For Sale 0.0 EUR